- Warehouse facilities
- Production workshops
Low rise, drum at the front.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥ 230; ≥ 260 (with ceiling drive) |
B, mm Opening width | B |
A, mm Angle track height | H + 110 |
Ab, mm Height of shaft axle and drum | ≥ A + 59 |
A1, mm Vertical track height | А - 543 |
A2, mm Horizontal track height | А - 106 |
E, mm Horizontal track length | Н + 300 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 |
P, mm Door opener position | Н + 1 185 |
n, mm Clear opening | Up to 190 — without drive, opening width up to 4 500; up to 235 — without drive, opening width more than 4 500; up to 10 — with ceiling drive, opening width up to 4 500; up to 70 — with ceiling drive, opening width over 4 500 |
Low rise, drum at the back.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥ 150 ≥ 180 (with ceiling drive) |
B, mm Opening width | B |
A, mm Angle track height | At h < 170: H + 110; at 150 ≤ h ≤ 170: H + h - 60 |
Ab, mm Height of shaft axle and drum | At h ≤ 170: H + 55; at 150 ≤ h ≤ 170: H + h - 47 |
A1, mm Vertical track height | А - 543 |
A2, mm Horizontal track height | А - 106 |
E, mm Horizontal track length | Н + 510 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 |
P, mm Door opener position | Н + 1 185 |
n, mm Clear opening | 240 (without drive); 40...60 (with ceiling drive) |
High rise.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | > 660 |
B, mm Opening width | B |
HL, mm Distance from opening to horizontal tracks level | Default h - 330 |
A, mm Angle track height | H + HL |
Ab, mm Height of shaft axle and drum | A + 86/97 |
A1, mm Vertical track height | А - 580 |
A2, mm Horizontal track height | А - 53 |
E, mm Horizontal track length | H - NL + 470...600 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 |
Q, mm Shaft opener position | 300 |
High lift, drum from below.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥1 600 |
B, mm Opening width | B |
HL, mm Distance from opening to horizontal tracks level | 1 330 ≤ HL ≤ h - 150 |
A, mm Angle track height | H + HL |
Ab, mm Height of shaft axle and drum | H + 400...600 + 280 |
A1, mm Vertical track height | А - 580 |
A2, mm Horizontal track height | А - 53 |
E, mm Horizontal track length | H - NL + 470...600 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | ≥ 300 |
Q, mm Shaft opener position | ≥ 500 |
Vertical lift.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | > Н + 500 |
B, mm Opening width | B |
A, mm Angle track height | 2H + 120 |
Ab, mm Height of shaft axle and drum | A + 166 |
S, mm Minimum side room clearance | 120 |
Q, mm Shaft opener position | 300 |
Vertical lift, drum from below.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | > H + 120 |
B, mm Opening width | B |
A, mm Angle track height | 2H + 120 |
Ab, mm Height of shaft axle and drum | H + 680 |
S, mm Minimum side room clearance | 500 min |
Q, mm Shaft opener position | ≥ 650 |
Standard lift.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | R381: ≥ 420; R305: ≥ 350 |
B, mm Opening width | B |
A, mm Angle track height | R381: H+235; R305: H+165 |
Ab, mm Height of shaft axle and drum | A + 97 |
A1, mm Vertical track height | R381: A - 580; R305: A - 490 |
A2, mm Horizontal track height | А - 110 |
E, mm Horizontal track length | R381: H+200; R305: H+250 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 |
P, mm Door opener position | H + 1 060 |
Q, mm Shaft opener position | 300 |
Parameter | Value | Notes |
---|---|---|
Wind load resistance, Pa, class (EN 12424) | 2 class (EN12424:2000) | |
Tightness | 4 class (EN12426:2000) | |
Water resistance limit - minutes, class (EN12425) | 3 class (EN12425:2000) | |
Sound insulation, dB | < 35 | |
Force of manual opening and closing, kg | Up to 22.5 | |
Door leaf weight, kg/m² | 5.3 | |
Metal thickness, mm | 0.4 or 0.6 | |
Number of cycles | 25 000 |
1. Sections of the door leaf must move smoothly along the guides, and the door itself must be balanced, i.e., its weight must be compensated by the torque of the springs.
2. Manual opening and closing of the gate is carried out only with the help of a handle.
3. When opening and closing the gate manually, do not apply much force to it. Sudden jerks are prohibited.
4. Make sure that people and animals are not in the area of the gate while it is operating.
5. It is strictly prohibited to move under the moving door leaf, as this can lead to injury.
6. Do not subject the gate to impacts or interfere with its free movement when opening and closing.
7. Make sure that there are no foreign objects or debris in the opening while the blade is moving. Their presence can lead to skewing and jamming of the door leaf.
8. Do not expose the guides and rollers to contamination, as this may impair smooth operation, and if there is an electric drive, this may lead to its overload and failure.
Packing in cardboard | Packaging features |
---|---|
Description | The guide system and panel of sectional doors have a rigid combined packaging made of cardboard and polystyrene foam, covered with stretch film; the installation kit is packed in a corrugated cardboard box and sealed with packaging film; All packages are equipped with information stickers containing order data, as well as the company logo |
Contents | Cardboard, polystyrene foam, stretch film, tape |
Width, mm | Shield packaging — from 500 to 800 |
Height, mm | Shield packaging — from 200 to 800 |
Length, mm | Shield packaging — from 2 100 to 8 100 |
Gross weight, kg | Up to 1 000 |
Number of items in the packaging | Shield packaging — from 3 to 17 panels; package of guides — 1 guide system; packaging of components — a box with a complete set (there may be several); additional packaging is possible (edging, delta profile, etc.) |
It is recommended to store sandwich panels in their original packaging in a horizontal position on a flat surface for no more than 6 months from the date of production in closed warehouses or under a canopy. The panels must be protected from direct sunlight, precipitation and contamination.
The buyer is provided with a 1 year warranty.
Low rise, drum at the front.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥ 230; ≥ 260 (with ceiling drive) |
B, mm Opening width | B |
A, mm Angle track height | H + 110 |
Ab, mm Height of shaft axle and drum | ≥ A + 59 |
A1, mm Vertical track height | А - 543 |
A2, mm Horizontal track height | А - 106 |
E, mm Horizontal track length | Н + 300 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 |
P, mm Door opener position | Н + 1 185 |
n, mm Clear opening | Up to 190 — without drive, opening width up to 4 500; up to 235 — without drive, opening width more than 4 500; up to 10 — with ceiling drive, opening width up to 4 500; up to 70 — with ceiling drive, opening width over 4 500 |
Low rise, drum at the back.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥ 150 ≥ 180 (with ceiling drive) |
B, mm Opening width | B |
A, mm Angle track height | At h < 170: H + 110; at 150 ≤ h ≤ 170: H + h - 60 |
Ab, mm Height of shaft axle and drum | At h ≤ 170: H + 55; at 150 ≤ h ≤ 170: H + h - 47 |
A1, mm Vertical track height | А - 543 |
A2, mm Horizontal track height | А - 106 |
E, mm Horizontal track length | Н + 510 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 |
P, mm Door opener position | Н + 1 185 |
n, mm Clear opening | 240 (without drive); 40...60 (with ceiling drive) |
High rise.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | > 660 |
B, mm Opening width | B |
HL, mm Distance from opening to horizontal tracks level | Default h - 330 |
A, mm Angle track height | H + HL |
Ab, mm Height of shaft axle and drum | A + 86/97 |
A1, mm Vertical track height | А - 580 |
A2, mm Horizontal track height | А - 53 |
E, mm Horizontal track length | H - NL + 470...600 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 |
Q, mm Shaft opener position | 300 |
High lift, drum from below.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥1 600 |
B, mm Opening width | B |
HL, mm Distance from opening to horizontal tracks level | 1 330 ≤ HL ≤ h - 150 |
A, mm Angle track height | H + HL |
Ab, mm Height of shaft axle and drum | H + 400...600 + 280 |
A1, mm Vertical track height | А - 580 |
A2, mm Horizontal track height | А - 53 |
E, mm Horizontal track length | H - NL + 470...600 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | ≥ 300 |
Q, mm Shaft opener position | ≥ 500 |
Vertical lift.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | > Н + 500 |
B, mm Opening width | B |
A, mm Angle track height | 2H + 120 |
Ab, mm Height of shaft axle and drum | A + 166 |
S, mm Minimum side room clearance | 120 |
Q, mm Shaft opener position | 300 |
Vertical lift, drum from below.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | > H + 120 |
B, mm Opening width | B |
A, mm Angle track height | 2H + 120 |
Ab, mm Height of shaft axle and drum | H + 680 |
S, mm Minimum side room clearance | 500 min |
Q, mm Shaft opener position | ≥ 650 |
Standard lift.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | R381: ≥ 420; R305: ≥ 350 |
B, mm Opening width | B |
A, mm Angle track height | R381: H+235; R305: H+165 |
Ab, mm Height of shaft axle and drum | A + 97 |
A1, mm Vertical track height | R381: A - 580; R305: A - 490 |
A2, mm Horizontal track height | А - 110 |
E, mm Horizontal track length | R381: H+200; R305: H+250 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 |
P, mm Door opener position | H + 1 060 |
Q, mm Shaft opener position | 300 |
Parameter | Value | Notes |
---|---|---|
Wind load resistance, Pa, class (EN 12424) | 2 class (EN12424:2000) | |
Tightness | 4 class (EN12426:2000) | |
Water resistance limit - minutes, class (EN12425) | 3 class (EN12425:2000) | |
Sound insulation, dB | < 35 | |
Force of manual opening and closing, kg | Up to 22.5 | |
Door leaf weight, kg/m² | 5.3 | |
Metal thickness, mm | 0.4 or 0.6 | |
Number of cycles | 25 000 |
1. Sections of the door leaf must move smoothly along the guides, and the door itself must be balanced, i.e., its weight must be compensated by the torque of the springs.
2. Manual opening and closing of the gate is carried out only with the help of a handle.
3. When opening and closing the gate manually, do not apply much force to it. Sudden jerks are prohibited.
4. Make sure that people and animals are not in the area of the gate while it is operating.
5. It is strictly prohibited to move under the moving door leaf, as this can lead to injury.
6. Do not subject the gate to impacts or interfere with its free movement when opening and closing.
7. Make sure that there are no foreign objects or debris in the opening while the blade is moving. Their presence can lead to skewing and jamming of the door leaf.
8. Do not expose the guides and rollers to contamination, as this may impair smooth operation, and if there is an electric drive, this may lead to its overload and failure.
Packing in cardboard | Packaging features |
---|---|
Description | The guide system and panel of sectional doors have a rigid combined packaging made of cardboard and polystyrene foam, covered with stretch film; the installation kit is packed in a corrugated cardboard box and sealed with packaging film; All packages are equipped with information stickers containing order data, as well as the company logo |
Contents | Cardboard, polystyrene foam, stretch film, tape |
Width, mm | Shield packaging — from 500 to 800 |
Height, mm | Shield packaging — from 200 to 800 |
Length, mm | Shield packaging — from 2 100 to 8 100 |
Gross weight, kg | Up to 1 000 |
Number of items in the packaging | Shield packaging — from 3 to 17 panels; package of guides — 1 guide system; packaging of components — a box with a complete set (there may be several); additional packaging is possible (edging, delta profile, etc.) |
It is recommended to store sandwich panels in their original packaging in a horizontal position on a flat surface for no more than 6 months from the date of production in closed warehouses or under a canopy. The panels must be protected from direct sunlight, precipitation and contamination.
The buyer is provided with a 1 year warranty.