en
  • en
  • cn

Industrial sectional door ISD01 China

Industrial sectional doors of the ISD01 China series are installed in openings of industrial buildings, warehouses, workshops, terminals and other industrial facilities, where they must meet strict requirements. Since industrial doors are operated with high intensity, to ensure long-term operation without failures, they have increased strength characteristics due to their reinforced design. The sealing system used in the sectional doors provides high thermal insulation — maintaining the required temperature conditions, which is an important task for almost any industrial facility.
Application:
  • Warehouse complexes
  • Production workshops
Advantages
The absence of a cold bridge in the sandwich panel and sealing along the entire contour due to seals guarantee maximum thermal efficiency of the door.
The variety of types of gate lifts allows you to install them in rooms with any geometry of the internal space.
Cable break and spring break protection systems prevent the blade from falling in emergency situations.
The design, proven over the years, and the safety margin of the components guarantee a long service life.
The absence of a cold bridge in the sandwich panel and sealing along the entire contour due to seals guarantee maximum thermal efficiency of the door.
The variety of types of gate lifts allows you to install them in rooms with any geometry of the internal space.
Cable break and spring break protection systems prevent the blade from falling in emergency situations.
The design, proven over the years, and the safety margin of the components guarantee a long service life.
Design
Panel design
Surface Type
Colors
D-Line
D-Line
S-Line
S-Line
V-Line
V-Line
M-Line
M-Line
Wood effect (outer side of the panel)
Wood effect (outer side of the panel)
Stucco (inside panel)
Stucco (inside panel)
RAL 9003 (white)
RAL 9003 (white)
RAL 9006 (silver)
RAL 9006 (silver)
RAL 7004 (grey)
RAL 7004 (grey)
RAL 1014 (beige)
RAL 1014 (beige)
RAL 6005 (green)
RAL 6005 (green)
RAL 5005 (blue)
RAL 5005 (blue)
RAL 7016 (anthracite)
RAL 7016 (anthracite)
RAL 3000 (red)
RAL 3000 (red)
RAL 3005 (burgundy)
RAL 3005 (burgundy)
RAL 8017 (brown-red)
RAL 8017 (brown-red)
Non-standard color according to RAL card (surcharge)
Non-standard color according to RAL card (surcharge)
Equipment
Standard
Optional
Canvas made of energy-efficient sandwich panels 40 mm thick and reinforced for internal hinges and side supports.

Canvas made of energy-efficient sandwich panels 40 mm thick and reinforced for internal hinges and side supports.

A set of guides and corner posts made of 2 mm thick steel has an increased margin of safety and has everything necessary for the installation of perforations.

A set of guides and corner posts made of 2 mm thick steel has an increased margin of safety and has everything necessary for the installation of perforations.

The torsion mechanism is designed for 25 000 cycles. The durability of the gate design ensures that the door opens and closes effortlessly.

The torsion mechanism is designed for 25 000 cycles. The durability of the gate design ensures that the door opens and closes effortlessly.

The spring break protection device blocks the shaft in emergency situations, which prevents the door leaf from falling.

The spring break protection device blocks the shaft in emergency situations, which prevents the door leaf from falling.

The cable break protection device is installed as a lower bracket on the door leaf. If the cable breaks, the mechanism is activated and prevents the door leaf from falling.

The cable break protection device is installed as a lower bracket on the door leaf. If the cable breaks, the mechanism is activated and prevents the door leaf from falling.

Box with installation kit, product data sheet and installation instructions.

Box with installation kit, product data sheet and installation instructions.

The ergonomic handle makes it easy and convenient to open and close the gate.

The ergonomic handle makes it easy and convenient to open and close the gate.

The special design of the windows (size 627 x 327 or 607 x 202 mm) ensures a tight fit to the door leaf, which protects it from freezing and heat loss. The windows are made with black frames.

The special design of the windows (size 627 x 327 or 607 x 202 mm) ensures a tight fit to the door leaf, which protects it from freezing and heat loss. The windows are made with black frames.

A mechanical lock allows you to block the door leaf in the closed position both from inside the room and from the street.

A mechanical lock allows you to block the door leaf in the closed position both from inside the room and from the street.

The gate has an improved design, is highly durable and has an aesthetic appearance. The minimum height of the shield is 2 130 mm.

The gate has an improved design, is highly durable and has an aesthetic appearance. The minimum height of the shield is 2 130 mm.

Possibility of gate automation with a drive and security systems (see section “Automation for gates”).

Possibility of gate automation with a drive and security systems (see section “Automation for gates”).

A manual chain drive is installed on industrial doors of all types and is used to raise and lower the door leaf manually.

A manual chain drive is installed on industrial doors of all types and is used to raise and lower the door leaf manually.

Torsion mechanism designed for a life of up to 100 000 cycles.

Torsion mechanism designed for a life of up to 100 000 cycles.

It is recommended to install an anti-corrosion package of components if the gate is used in conditions of high humidity to ensure reliable protection against corrosion and stable operation of the gate. This package has an increased service life and includes: a painted spring, painted guides, stainless side supports, hinges and hardware, a stainless cable, painted side covers.

It is recommended to install an anti-corrosion package of components if the gate is used in conditions of high humidity to ensure reliable protection against corrosion and stable operation of the gate. This package has an increased service life and includes: a painted spring, painted guides, stainless side supports, hinges and hardware, a stainless cable, painted side covers.

Technical description
Size Table
Opening Dimensions
Construction
Standard Construction
Specifications
Operating Conditions
Packaging
Parameters
Value
Opening height, mm
2 000–8 000
Opening width, mm
2 000–8 000
Headroom, mm
From 230
Sideroom clearance, mm
From 120
  1. Vertical guide
  2. Corner post
  3. Cylindrical shaft
  4. Spring break protection device
  5. Drum
  6. U-shaped bracket
  7. Balancing spring mechanism (torsion spring)
  8. Connecting coupling
  9. Internal support bracket
  10. Upper support with roller holder
  11. Side support with roller holder
  12. Reinforcing delta profile
  13. Cable break protection device
  14. Sandwich panel
  15. Inner loop
  16. Bottom profile and seal
  17. Side seal
  18. Top profile
  19. Upper seal
  20. Side cover for panels with mounting holes
  21. Handle "step"
  22. Spring shock absorber
  23. Ceiling mounting bracket

Low rise, drum at the front.

Low rise, drum at the front.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height ≥ 230; ≥ 260 (with ceiling drive)
B, mm Opening width B
A, mm Angle track height H + 110
Ab, mm Height of shaft axle and drum ≥ A + 59
A1, mm Vertical track height А - 543
A2, mm Horizontal track height А - 106
E, mm Horizontal track length Н + 300
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance 120
P, mm Door opener position Н + 1 185
n, mm Clear opening Up to 190 — without drive, opening width up to 4 500; up to 235 — without drive, opening width more than 4 500; up to 10 — with ceiling drive, opening width up to 4 500; up to 70 — with ceiling drive, opening width over 4 500
High rise.

High rise.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height > 660
B, mm Opening width B
HL, mm Distance from opening to horizontal tracks level Default h - 330
A, mm Angle track height H + HL
Ab, mm Height of shaft axle and drum A + 86/97
A1, mm Vertical track height А - 580
A2, mm Horizontal track height А - 53
E, mm Horizontal track length H - NL + 470...600
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance 120
Q, mm Shaft opener position 300
High lift, drum from below.

High lift, drum from below.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height ≥1 600
B, mm Opening width B
HL, mm Distance from opening to horizontal tracks level 1 330 ≤ HL ≤ h - 150
A, mm Angle track height H + HL
Ab, mm Height of shaft axle and drum H + 400...600 + 280
A1, mm Vertical track height А - 580
A2, mm Horizontal track height А - 53
E, mm Horizontal track length H - NL + 470...600
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance ≥ 300
Q, mm Shaft opener position ≥ 500
Vertical lift.

Vertical lift.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height > Н + 500
B, mm Opening width B
A, mm Angle track height 2H + 120
Ab, mm Height of shaft axle and drum A + 166
A1, mm Vertical track height Н
S, mm Minimum side room clearance 120
Q, mm Shaft opener position 300
Vertical lift, drum from below.

Vertical lift, drum from below.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height > H + 120
B, mm Opening width B
A, mm Angle track height 2H + 120
Ab, mm Height of shaft axle and drum H + 680
S, mm Minimum side room clearance 500 min
Q, mm Shaft opener position ≥ 650
Standard lift.

Standard lift.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height R381: ≥ 420; R305: ≥ 350
B, mm Opening width B
A, mm Angle track height R381: H+235; R305: H+165
Ab, mm Height of shaft axle and drum A + 97
A1, mm Vertical track height R381: A - 580; R305: A - 490
A2, mm Horizontal track height А - 110
E, mm Horizontal track length R381: H+200; R305: H+250
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance 120
P, mm Door opener position Н + 1 060
Q, mm Shaft opener position 300
Parameter Value Notes
Heat transfer resistance of the fabric, m² * °C/W 1.13 The value depends on the size of the door, indicated for doors measuring 3 500 x 3 000 mm
Wind load resistance, Pa, class (EN 12424) 2 class (EN12424:2000)
Tightness 4 class (EN12426:2000)
Water resistance limit - minutes, class (EN12425) 3 class (EN12425:2000)
Sound insulation, dB < 35
Force of manual opening and closing, kg Up to 22.5
Door leaf weight, kg/m² 10.9 The exact value depends on the size of the panels used in the gate construction
Panel thickness, mm 40
Metal thickness, mm 0.4
Number of cycles 25 000

1. Sections of the door leaf must move smoothly along the guides, and the door itself must be balanced, i.e., its weight must be compensated by the torque of the springs.

2. Manual opening and closing of the gate is carried out only with the help of a handle.

3. When opening and closing the gate manually, do not apply much force to it. Sudden jerks are prohibited.

4. Make sure that people and animals are not in the area of the gate while it is operating.

5. It is strictly prohibited to move under the moving door leaf, as this can lead to injury.

6. Do not subject the gate to impacts or interfere with its free movement when opening and closing.

7. Make sure that there are no foreign objects or debris in the opening while the blade is moving. Their presence can lead to skewing and jamming of the door leaf.

8. Do not expose the guides and rollers to contamination, as this may impair smooth operation, and if there is an electric drive, this may lead to its overload and failure.

Packing in cardboard Packaging features
Description The guide system and panel of sectional doors have a rigid combined packaging made of cardboard and polystyrene foam, covered with stretch film; the installation kit is packed in a corrugated cardboard box and sealed with packaging film; All packages are equipped with information stickers containing order data, as well as the company logo
Contents Cardboard, polystyrene foam, stretch film, tape
Width, mm Shield packaging — from 500 to 800
Height, mm Shield packaging — from 200 to 800
Length, mm Shield packaging — from 2 100 to 8 100
Gross weight, kg Up to 1 000
Number of items in the packaging Shield packaging — from 3 to 17 panels; package of guides — 1 guide system; packaging of components — a box with a complete set (there may be several); additional packaging is possible (edging, delta profile, etc.)
Additional Information print

It is recommended to store sandwich panels in their original packaging in a horizontal position on a flat surface for no more than 6 months from the date of production in closed warehouses or under a canopy. The panels must be protected from direct sunlight, precipitation and contamination.

Installation
Mounting Options
Checking Dimensional Details
Surface mounting: the guide system is mounted on the walls and lintel from the inside of the opening.
  1. To take the necessary indicators, a tape measure and a building level are enough. All measurements are taken indoors. Each value must be measured at least at three points (in extreme positions and in the center).
  2. H is the height of the opening (distance from the floor to the top of the opening).
  3. B is the width of the opening (the distance from the left to the right edge of the opening).
  4. h — lintel (distance from the top of the opening to the ceiling) min 150 mm.
  5. b1/ b2 — left/right side distance (distance from the corresponding edge of the opening to the obstacle) min 120 mm.
  6. L is the depth of the room.
  7. When measuring H and B, the largest value is taken as the final size.
  8. When measuring h, b1, b2 and L, the smallest value is taken.
  9. The difference in floor level across the entire width of the opening should not exceed 10 mm. It is necessary to ensure that the mounting plane (walls and ceiling) is maintained. The base for installing the guide system must be monolithic and durable; if this is not available, additional edging or the formation of an opening with metal products is required.
Warranty print

The buyer is provided with a 1 year warranty.

New Products
The lightweight cylindrical shaft system on a 60 x 40 mm pipe is a more affordable option for gates up to 4 750 x 3 500 mm in size.

The lightweight cylindrical shaft system on a 60 x 40 mm pipe is a more affordable option for gates up to 4 750 x 3 500 mm in size.

The lightweight bracket system simplifies the installation of a remote system with a cylindrical shaft from below (on a 100 x 100 pipe), while being highly durable and reliable. The requirements for the walls are reduced by mounting the system through a corner post. The absence of additional elements for preparing the opening reduces the weight of the structure and reduces installation time.

The lightweight bracket system simplifies the installation of a remote system with a cylindrical shaft from below (on a 100 x 100 pipe), while being highly durable and reliable. The requirements for the walls are reduced by mounting the system through a corner post. The absence of additional elements for preparing the opening reduces the weight of the structure and reduces installation time.

The drive mounting bracket allows you to install a shaft from below on a remote mounting system on a 100 x 100 mm pipe for all types of shaft drives manufactured by DoorHan.

The drive mounting bracket allows you to install a shaft from below on a remote mounting system on a 100 x 100 mm pipe for all types of shaft drives manufactured by DoorHan.

All drums have holes for the cable, which greatly simplifies installation and ensures reliable fixation of the cable.

All drums have holes for the cable, which greatly simplifies installation and ensures reliable fixation of the cable.

Design
Panel design
D-Line
D-Line
S-Line
S-Line
V-Line
V-Line
M-Line
M-Line
Surface Type
Wood effect (outer side of the panel)
Wood effect (outer side of the panel)
Stucco (inside panel)
Stucco (inside panel)
Colors
RAL 9003 (white)
RAL 9003 (white)
RAL 9006 (silver)
RAL 9006 (silver)
RAL 7004 (grey)
RAL 7004 (grey)
RAL 1014 (beige)
RAL 1014 (beige)
RAL 6005 (green)
RAL 6005 (green)
RAL 5005 (blue)
RAL 5005 (blue)
RAL 7016 (anthracite)
RAL 7016 (anthracite)
RAL 3000 (red)
RAL 3000 (red)
RAL 3005 (burgundy)
RAL 3005 (burgundy)
RAL 8017 (brown-red)
RAL 8017 (brown-red)
Non-standard color according to RAL card (surcharge)
Non-standard color according to RAL card (surcharge)
Equipment
Standard
Canvas made of energy-efficient sandwich panels 40 mm thick and reinforced for internal hinges and side supports.

Canvas made of energy-efficient sandwich panels 40 mm thick and reinforced for internal hinges and side supports.

A set of guides and corner posts made of 2 mm thick steel has an increased margin of safety and has everything necessary for the installation of perforations.

A set of guides and corner posts made of 2 mm thick steel has an increased margin of safety and has everything necessary for the installation of perforations.

The torsion mechanism is designed for 25 000 cycles. The durability of the gate design ensures that the door opens and closes effortlessly.

The torsion mechanism is designed for 25 000 cycles. The durability of the gate design ensures that the door opens and closes effortlessly.

The spring break protection device blocks the shaft in emergency situations, which prevents the door leaf from falling.

The spring break protection device blocks the shaft in emergency situations, which prevents the door leaf from falling.

The cable break protection device is installed as a lower bracket on the door leaf. If the cable breaks, the mechanism is activated and prevents the door leaf from falling.

The cable break protection device is installed as a lower bracket on the door leaf. If the cable breaks, the mechanism is activated and prevents the door leaf from falling.

Box with installation kit, product data sheet and installation instructions.

Box with installation kit, product data sheet and installation instructions.

The ergonomic handle makes it easy and convenient to open and close the gate.

The ergonomic handle makes it easy and convenient to open and close the gate.

Optional
The special design of the windows (size 627 x 327 or 607 x 202 mm) ensures a tight fit to the door leaf, which protects it from freezing and heat loss. The windows are made with black frames.

The special design of the windows (size 627 x 327 or 607 x 202 mm) ensures a tight fit to the door leaf, which protects it from freezing and heat loss. The windows are made with black frames.

A mechanical lock allows you to block the door leaf in the closed position both from inside the room and from the street.

A mechanical lock allows you to block the door leaf in the closed position both from inside the room and from the street.

The gate has an improved design, is highly durable and has an aesthetic appearance. The minimum height of the shield is 2 130 mm.

The gate has an improved design, is highly durable and has an aesthetic appearance. The minimum height of the shield is 2 130 mm.

Possibility of gate automation with a drive and security systems (see section “Automation for gates”).

Possibility of gate automation with a drive and security systems (see section “Automation for gates”).

A manual chain drive is installed on industrial doors of all types and is used to raise and lower the door leaf manually.

A manual chain drive is installed on industrial doors of all types and is used to raise and lower the door leaf manually.

Torsion mechanism designed for a life of up to 100 000 cycles.

Torsion mechanism designed for a life of up to 100 000 cycles.

It is recommended to install an anti-corrosion package of components if the gate is used in conditions of high humidity to ensure reliable protection against corrosion and stable operation of the gate. This package has an increased service life and includes: a painted spring, painted guides, stainless side supports, hinges and hardware, a stainless cable, painted side covers.

It is recommended to install an anti-corrosion package of components if the gate is used in conditions of high humidity to ensure reliable protection against corrosion and stable operation of the gate. This package has an increased service life and includes: a painted spring, painted guides, stainless side supports, hinges and hardware, a stainless cable, painted side covers.

Technical description
Size Table
Parameters
Value
Opening height, mm
2 000–8 000
Opening width, mm
2 000–8 000
Headroom, mm
From 230
Sideroom clearance, mm
From 120
Construction
  1. Vertical guide
  2. Corner post
  3. Cylindrical shaft
  4. Spring break protection device
  5. Drum
  6. U-shaped bracket
  7. Balancing spring mechanism (torsion spring)
  8. Connecting coupling
  9. Internal support bracket
  10. Upper support with roller holder
  11. Side support with roller holder
  12. Reinforcing delta profile
  13. Cable break protection device
  14. Sandwich panel
  15. Inner loop
  16. Bottom profile and seal
  17. Side seal
  18. Top profile
  19. Upper seal
  20. Side cover for panels with mounting holes
  21. Handle "step"
  22. Spring shock absorber
  23. Ceiling mounting bracket
Standard Construction

Low rise, drum at the front.

Low rise, drum at the front.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height ≥ 230; ≥ 260 (with ceiling drive)
B, mm Opening width B
A, mm Angle track height H + 110
Ab, mm Height of shaft axle and drum ≥ A + 59
A1, mm Vertical track height А - 543
A2, mm Horizontal track height А - 106
E, mm Horizontal track length Н + 300
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance 120
P, mm Door opener position Н + 1 185
n, mm Clear opening Up to 190 — without drive, opening width up to 4 500; up to 235 — without drive, opening width more than 4 500; up to 10 — with ceiling drive, opening width up to 4 500; up to 70 — with ceiling drive, opening width over 4 500
High rise.

High rise.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height > 660
B, mm Opening width B
HL, mm Distance from opening to horizontal tracks level Default h - 330
A, mm Angle track height H + HL
Ab, mm Height of shaft axle and drum A + 86/97
A1, mm Vertical track height А - 580
A2, mm Horizontal track height А - 53
E, mm Horizontal track length H - NL + 470...600
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance 120
Q, mm Shaft opener position 300
High lift, drum from below.

High lift, drum from below.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height ≥1 600
B, mm Opening width B
HL, mm Distance from opening to horizontal tracks level 1 330 ≤ HL ≤ h - 150
A, mm Angle track height H + HL
Ab, mm Height of shaft axle and drum H + 400...600 + 280
A1, mm Vertical track height А - 580
A2, mm Horizontal track height А - 53
E, mm Horizontal track length H - NL + 470...600
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance ≥ 300
Q, mm Shaft opener position ≥ 500
Vertical lift.

Vertical lift.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height > Н + 500
B, mm Opening width B
A, mm Angle track height 2H + 120
Ab, mm Height of shaft axle and drum A + 166
A1, mm Vertical track height Н
S, mm Minimum side room clearance 120
Q, mm Shaft opener position 300
Vertical lift, drum from below.

Vertical lift, drum from below.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height > H + 120
B, mm Opening width B
A, mm Angle track height 2H + 120
Ab, mm Height of shaft axle and drum H + 680
S, mm Minimum side room clearance 500 min
Q, mm Shaft opener position ≥ 650
Standard lift.

Standard lift.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height R381: ≥ 420; R305: ≥ 350
B, mm Opening width B
A, mm Angle track height R381: H+235; R305: H+165
Ab, mm Height of shaft axle and drum A + 97
A1, mm Vertical track height R381: A - 580; R305: A - 490
A2, mm Horizontal track height А - 110
E, mm Horizontal track length R381: H+200; R305: H+250
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance 120
P, mm Door opener position Н + 1 060
Q, mm Shaft opener position 300
Specifications
Parameter Value Notes
Heat transfer resistance of the fabric, m² * °C/W 1.13 The value depends on the size of the door, indicated for doors measuring 3 500 x 3 000 mm
Wind load resistance, Pa, class (EN 12424) 2 class (EN12424:2000)
Tightness 4 class (EN12426:2000)
Water resistance limit - minutes, class (EN12425) 3 class (EN12425:2000)
Sound insulation, dB < 35
Force of manual opening and closing, kg Up to 22.5
Door leaf weight, kg/m² 10.9 The exact value depends on the size of the panels used in the gate construction
Panel thickness, mm 40
Metal thickness, mm 0.4
Number of cycles 25 000
Operating Conditions

1. Sections of the door leaf must move smoothly along the guides, and the door itself must be balanced, i.e., its weight must be compensated by the torque of the springs.

2. Manual opening and closing of the gate is carried out only with the help of a handle.

3. When opening and closing the gate manually, do not apply much force to it. Sudden jerks are prohibited.

4. Make sure that people and animals are not in the area of the gate while it is operating.

5. It is strictly prohibited to move under the moving door leaf, as this can lead to injury.

6. Do not subject the gate to impacts or interfere with its free movement when opening and closing.

7. Make sure that there are no foreign objects or debris in the opening while the blade is moving. Their presence can lead to skewing and jamming of the door leaf.

8. Do not expose the guides and rollers to contamination, as this may impair smooth operation, and if there is an electric drive, this may lead to its overload and failure.

Packaging
Packing in cardboard Packaging features
Description The guide system and panel of sectional doors have a rigid combined packaging made of cardboard and polystyrene foam, covered with stretch film; the installation kit is packed in a corrugated cardboard box and sealed with packaging film; All packages are equipped with information stickers containing order data, as well as the company logo
Contents Cardboard, polystyrene foam, stretch film, tape
Width, mm Shield packaging — from 500 to 800
Height, mm Shield packaging — from 200 to 800
Length, mm Shield packaging — from 2 100 to 8 100
Gross weight, kg Up to 1 000
Number of items in the packaging Shield packaging — from 3 to 17 panels; package of guides — 1 guide system; packaging of components — a box with a complete set (there may be several); additional packaging is possible (edging, delta profile, etc.)
Additional Information

It is recommended to store sandwich panels in their original packaging in a horizontal position on a flat surface for no more than 6 months from the date of production in closed warehouses or under a canopy. The panels must be protected from direct sunlight, precipitation and contamination.

Installation
Mounting Options
Surface mounting: the guide system is mounted on the walls and lintel from the inside of the opening.
Checking Dimensional Details
  1. To take the necessary indicators, a tape measure and a building level are enough. All measurements are taken indoors. Each value must be measured at least at three points (in extreme positions and in the center).
  2. H is the height of the opening (distance from the floor to the top of the opening).
  3. B is the width of the opening (the distance from the left to the right edge of the opening).
  4. h — lintel (distance from the top of the opening to the ceiling) min 150 mm.
  5. b1/ b2 — left/right side distance (distance from the corresponding edge of the opening to the obstacle) min 120 mm.
  6. L is the depth of the room.
  7. When measuring H and B, the largest value is taken as the final size.
  8. When measuring h, b1, b2 and L, the smallest value is taken.
  9. The difference in floor level across the entire width of the opening should not exceed 10 mm. It is necessary to ensure that the mounting plane (walls and ceiling) is maintained. The base for installing the guide system must be monolithic and durable; if this is not available, additional edging or the formation of an opening with metal products is required.
Warranty

The buyer is provided with a 1 year warranty.

Checkout
Managers of the company will answer all
questions by phone: